Tên thương hiệu: | HongCe |
Số mẫu: | HL-1 |
MOQ: | 1 set |
giá bán: | Negotiatable |
Điều khoản thanh toán: | T/T |
Khả năng cung cấp: | 10 Sets per month |
Professional Handheld Lamp Impact Resistance Tester | IEC 60598-2-8 Compliant | Portable Luminaire Safety Testing Equipment | 400mm & 1000mm Drop Heights | Durable Construction
Product introduction for Light Testing Equipment:
Our handlamp testing gadget meets all the guidelines in IEC60598-2-8:2007, specifically section 8.6.6.2 and the setup shown in Figure 1. It's built to see how tough handlamps are. This machine needs to be bolted straight onto a strong wall made of brick, stone, concrete, or something just as solid. And remember, it's operated by hand.
I would like to continue expand on this topic, how does this device work, what are the detailed steps to use it. In order to make it more comprehensive for marketing material for potential customers to understand and buy.
Application for Light Testing Equipment:
It is used to test the impact resistance of hand lamps.
Parameters for Light Testing Equipment:
Model | HL-1 |
Product name | Impact Tester for Handlamps |
Bar size | 40mm×40mm×5mm right-angle section with the corner rounded to a radius of 5mm. |
Impact height | 400mm/1000mm |
External dimensions | 1250mm×1500mm×200mm |
Material | Stainless steel and aluminum |
Test procedure for Light Testing Equipment:
The handlamp, missing its lamp, hangs by its cord with point a (see Figure 1) touching the bar's corner. The suspension point is 400 mm above the bar. Pull the lamp away from the wall until the cord is level, then let it hit the bar.
Do this three times at point a, then repeat at points b and c.
After this, the lamp should still be safe and usable. Repeat the whole test, but with the suspension point 1 m above the bar.
Again, the lamp must still be safe and usable.
The lamp's protective parts should stay in place, even if bent. If the glass or clear cover breaks but isn't the only protection, it's okay.