Certification delays are rarely caused by a bad motor. They are caused by a test report that answers the wrong question. Six measurements settle most small-motor approvals — if the bench can produce them under 8,000 r/min.
Small motors keep getting faster. Appliance, power-tool and pump duty points that used to sit near 3,000 r/min now run at 8,000 r/min and above, with torque in the fractional range of 0.5–1.7 N·m. On a bench sized for larger machines, that is a measurement problem: the transducer's lower limit sits right where the useful data lives. A IEC60334 dynamometer test bench pairs an 8,000 r/min ceiling with a 0.5–1.7 N·m torque window, PLC control and an aluminium alloy control cabinet, on AC 220 V 50 Hz supply.
| Item | Deliverable | Typical use |
|---|---|---|
| DC resistance | Cold / hot values, delta | Winding health, temperature baseline |
| No-load curve | Current, power, losses vs. voltage | Iron and mechanical loss split |
| Locked-rotor | Torque and current vs. voltage | Starting performance, protection setting |
| Load curve | Efficiency vs. output | Declared efficiency, buyer comparison |
| Temperature rise | Winding / core rise at rated load | Insulation class justification |
| T-N curve | Torque vs. speed, full band | Stall margin, switch-out speed |
Two avoidable failures dominate. First, tests run at a single voltage, which makes the results non-comparable when the destination market differs. Second, no-load and locked-rotor data taken on the same day as the load test without stabilisation — leaving temperature drift inside the efficiency numbers. Fixing the sequence is free; re-running a certification file is not.
Where the duty point sits slightly differently, the motor performance testing system covers the same 8,000 r/min class with the same 0.5–1.7 N·m window and PLC control, while the low-speed high-torque dynamometer bench variant targets lower-speed, higher-torque duty with the same accuracy philosophy. All three are built by Guangzhou Hejin Automation Control Technology Co., Ltd., a Guangzhou manufacturer since 2003 with 50–60% of output exported, and shipped with a documented acceptance run plus a one-year warranty.
Does the bench cover single-phase and three-phase motors? Yes — the T-N routine includes the centrifugal switch drop-out test specific to single-phase induction motors.
Can the T-N curve be exported? Test data is logged automatically and exportable for the certification file.
What supply does it need? AC 220 V 50 Hz for the standard configuration.